01 / 06
↗ Lighting Plot
02 / 06
Technical Notes
- Power distribution mismatch: wall outlets were dual phase rather than the modern standard 3-phase. The provided power distro had been modified and re-terminated to match, making its breakers unreliable for overload protection. Verified wiring with a multimeter and managed load manually.
03 / 06
Technical Notes
- Small and partially inexperienced crew with a compressed load-in window.
- Obstructions in the stage wash required on-the-fly focus adjustments to maintain full coverage.
↗ Lighting Plot
04 / 06
Technical Notes
- Used dynamic lighting programming to drive audience energy and engagement toward the live band — transitioning a hesitant crowd into active participation through intentional cueing.
05 / 06
Technical Notes
- Ground-supported crank-up truss structure shared with LED video wall. Fixture hang required lift access; truss access had to be carefully coordinated with video department — lighting and video could not work the structure simultaneously.
- Complex rigging logistics in a compact footprint; sequenced department access to maintain schedule.
06 / 06
Technical Notes
- Client requested a full color scheme change 30 minutes before doors — reprogrammed all relevant cues and positioned additional uplights around the room without delaying the event.